Plan a Keor MP UPS system

For a modular power-backup requirement, provide present load, expansion plans, redundancy needs and target backup duration. Battery selection, site conditions, monitoring and commissioning requirements should be confirmed in the project proposal.

IT enquiries across Jharkhand and West Bengal

Dhanbad Sales welcomes enquiries from individuals, students, homes, businesses, educational institutions, healthcare, hospitality, retail, industry, NGOs and government across the entirety of Jharkhand and West Bengal. Share your required quantity, application, budget, timeline and delivery PIN code.

The exact model, configuration, software licensing, compatibility, current price, availability and applicable warranty or support terms are confirmed in the quotation. Delivery, setup and installation feasibility are assessed for your location. Brand sourcing is confirmed per enquiry; this listing does not imply manufacturer authorisation.

Product enquiry on WhatsApp | Call 87952 51777 | Request an IT quotation

Explore computers, UPS and IT products

Keor MP is a three-phase online double-conversion UPS with a module-based architecture, engineered on three-level IGBT inverter technology for high efficiency in a compact design. Its footprint is up to 43% smaller than conventional UPS systems, and N+X redundancy keeps critical loads protected as capacity scales to 1.2 MW. Keor MP is the ideal solution for businesses that need future-ready power in a minimal footprint.

  • Up to 96% efficiency
  • Footprint up to 43% smaller than conventional UPS
  • Li-ion battery integration
  • Scales to 1.2 MW
  • ominal Power [kVA]
    Possible Classification True Online Double Conversion, VFI – SS – 111
    Possible configuration 3 phase + N + PE
    Specifications
    Input power factor
    Module-based Monolithic UPS with fault tolerance
    380-400-415 VAC
    310~480 VAC at full load
    50 / 60 Hz (40 to 70 Hz)
    Input phases 3 phase + N + PE
    Input THDi (at rated linear load) < 3%
    0.99
    Nominal Output voltage 380/400/415 VAC
    Output Voltage Regulation ±1 (Balanced Load)
    Output Power Factor 1
    Output frequency 50/60 Hz
    Crest Factor 3:1
    Output Voltage THD <2% for Linear Load & < 4% for Non Linear load
    Efficiency at rated load Up to 96%
    Efficiency on Eco mode
    Permitted overload on mains (PF=1)*
    Up to 99%
    ≤110% @ 30 mins, ≤125% @ 10min, ≤150% @ 1min
    Bypass Inbuilt Static & Maintenance Bypass
    Cabinet displays
    Communication ports MODBUS RS485/Rs 232/USB/Ethernet/SNMP, & Dry Contacts (optional)
    7” Touch screen color display cabinet and Multicolor status indicator (green/yellow/red)
    Cold start
    Maximum number of parallel chassis Max 6 cabinets
    Configurable acoustic alarms and signals
    Yes, optional
    Overload, Short circuit, Back feed port available (external connectional optional)
    all MCCBs, Over & Low voltage, Fast acting fuses
    EPO
    Alarm & Signals
    Temperature Sensor
    Safety and
    Protection
    Yes
    Yes
    Battery type/range voltage VRLA, Ni Cd & Li-ion
    Nominal Battery Voltage 432 VDC~600 VDC
    Charging mode 3 stage advanced cycle
    Overall Net weight (Kgs)
    Frame Dimensions (W X D X H) in mm 442 x 850 x 1200
    Ingress Protection
    Color Shade
    Cable entry
    110 140
    250 x 850
    x 1000
    IP20
    RAL 9005+9003
    60-160 kVA rear bottom entry, 200 kVA front & rear bottom entry
    160 170 205 220
    Operating Temperature 0 – 40 °C
    Operating Humidity 20% – 95% non- condensing
    Operating Altitude Upto 1000 mean sea level w/o deration
    Storage Temperature
    Maximum noise audible at 1m [dBA] 58 60 62 62 63 66
    20 – 55 °C
    GENERAL SPECIFICATIONS
    INPUT SPECIFICATIONS
    OUTPUT SPECIFICATIONS
    BATTERIES
    COMMUNICATION AND MANAGEMENT
    MECHANICAL CHARACTERISTICS
    CONFORMITY
    AMBIENT CONDITIONS
    Safety
    EMC
    Performance
    Environmental
    * at 30 Deg C
    Declarations
    IEC 62040-1
    IEC 62040-2
    IEC 62040-3
    IEC 62040-4
    RoHS / REACH
    ≤110% @30min
    ≤125% @1min
    Three-Phase UPS
    60 kVA – 200 kVA
    LGR 311235 LGR 311237 LGR 311239 LGR 311240 LGR 311241 LGR 311242
    60 80 100 120 160 200
    60 80 100 120 160 200
    Input voltage
    Input frequency
    Input voltage range
    Active power (kW)